Type 50051.0011
calcPageSize())" loading="lazy" />The product shown in the picture may differ from the product sold.
Field of application
Applications:
Provided as safety device for protection against excessive pressure
in pressure vessels, especially for coffee machines.
Approved for non-toxic gases and vapours.
Working temperature: -10°C / +14°F (263K) up to +160°C / +320°F (433K)
For saturated steam use only up to 4 bar and +150°C / +302°F (423K)
Description
Safety Valves, angle type, brass, type tested TÜV-SV.1009. S/G
Standard safety valve
with EPDM valve seal for vapours and gases
open bonnet, with lifting device
Outlet: female thread M15x1 with installed hose nozzle
Inlet: male thread type G (BSPP) acc. to ISO 228/1
Part No. 50051.0011.0000
Available options - on request only:
· hose nozzle acc. to customer specification
· body material CW509L
Data sheets
Live Stock: Out-Of Stock pcs (ON STOCK)
| Type (Series) | 50051,0011 |
|---|---|
| Solution | Air Gases |
| Solution Area | Storage, Processes |
| SKU | IN_50051_0011 |

Materials |
DIN EN |
ASME/ASTM |
|
|---|---|---|---|
1 |
Body |
CW614N |
B 249 UNS C38500 |
2 |
Disc |
CW614N |
B 249 UNS C38500 |
3 |
Valve seal |
EPDM |
|
4 |
Stem |
CW614N |
B 249 UNS C38500 |
5 |
Bonnet |
CW614N |
B 249 UNS C38500 |
6 |
Spring |
1.4571 |
A 313 Grade 316Ti |
7 |
Lifting device |
CW614N |
B 249 UNS C38500 |
8 |
Closing cap |
CC507L |
B 36 UNS C26800 |
9 |
Hose nozzle |
CW614N |
B 249 UNS C38500 |
Type 50051.0011 |
Technical data |
|
|---|---|---|
Nominal size |
GW |
3/8 |
Orifice |
d0 |
7 |
Set pressure range |
bar |
1.5-5.0 |
Hose nozzle-Ø |
M |
14.5 |
Height |
H |
64 |
Length |
L1 |
28.5 |
Length |
L2 |
13 |
Length |
A1 |
12 |
Wrench size across flats |
S1 |
27 |
Wrench size across flats |
S2 |
17 |
Weight |
ca. kg |
0.16 |
Coeff. of discharge from 2.0 bar |
αw |
0.42 |
Selected portfolio